| Sign In | Join Free | My uabig.com |
|
Brand Name : LLH
Model Number : M-LBS 5000
Place of Origin : China
MOQ : 1 pcs
Price : $350USD
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 800 units/month
Delivery Time : 5-8 work days
Packaging Details : 1 pcs/Box
Productname : Lightning Protection Box
Standards : IEC 61643-1
Operatingvoltage : 220V
Warrantyperiod : 2 years
Protectionlevel : IP65
Maximumcurrent : 100kA
Product Size : 510mmx370mmx140mm
Imax : 100kA
| Product Features |
|
● The high current, low residual voltage, and lightning protection modules are pluggable and have a built-in lightning status monitoring (counting) system, which can monitor and alarm the operation of the lightning protection box.
|
|
●The three-phase AC power series lightning protection box is applied to LPZ 0B-1 and subsequent partitions, installed in highly concentrated equipment rooms such as communication base station rooms, broadcasting and television system rooms, computer rooms, and medical equipment rooms. It can provide lightning protection for the three-phase AC distribution system in the computer room.
|
Products Description

| Standards | IEC 61643.11 |
| Models | M-LBS 5000 |
| Nominal operating voltage Un | 220Vac(50Hz) |
| Maximum continuous operating voltage Uc |
L-N:385Vac(50Hz) N-E:255Vac(50Hz) |
| Power W | 30KW,45A(Line) |
| L-N Impulse current(8/20μs) | 20kA/50kA/100kA |
| Voltage protection level Up | ≤1000V/≤1150V/≤1250V |
| Response time tA | ≤25ns |
| Protection Circuit | L1,L2,L3-N,N-E |
| Auxiliary functions | Number of lightning strikes, sound and light alarms, remote signaling dry contacts |
| Counting current range | 0.5A(8/20μs)-100kA(8/20μs) |
| Counting digit | 0-999 |
Mechanical parameters
| Installation method | Auxiliary installation bracket; Hole spacing 330mmx263mm |
| Screw torque | 5N*m |
| Strip length | 12mm |
| Wiring cross-sectional area | 6mm²-32mm² |
| Product size | 510mmx370mmx140mm |
| Shell material and flame retardant grade | Cold rolled steel plate painted orange |
| Deterioration indication | LED green: OK; Red: Fail; SPD failure buzzer alarm |
| Remote signaling contact type | Normally closed and normally open switching contacts |
| Remote signaling contact switching ability | 125 Vac / 1 A, 125 Vdc A / 0.2 |
| Maximum connection capacity of remote signaling | 2.5mm² |
| Installation position | Indoor |
| Temperature range | -40℃…+80℃ |
| Humidity range | Relative humidity ≤ 95% (max 40 ℃) |